Vital Signs Monitoring System M 1000

Vital Signs Monitoring System M 1000

Key Features

  • 10.4 inch Color TFT Display with 4 waveforms
  • Parameters includes ECG/RESP, SpO2 , NIBP,
    TEMP and Pulse Rate
  • Maximum 72-hour graphic and tabular trends
    of all parameters
  • Suitable for adult, pediatric and neonatal patient
  • ST Segment Analysis
  • Arrhythmia Analysis
  • Networking Capability
  • Pacemaker Detection
  • Drug Calculations & Titration Table
  • Alarm recall - 60 latest events with waveforms
  • In-built rechargeable Battery

Description

Designed & manufactured under extremely high level of quality control measures – to meet the expectations of demanding professionals; monitors almost all the patients in the toughest hospital environs.

Large bright TFT Display – easy to read from a distance in most of the light conditions, with a reliable long-life re-chargeable battery to manage any eventuality.

Technical Specifications

Safety
Meets the requirements of IEC 60601 series standards  
Dimension and Weight
Dimension: 318mm(W) x 264mm(H) x 152mm (D)
Weight: 5.5 kg
Operation Environment
Power: AC100~250V, 50/60 Hz
Temperature: 0~40 °C
Humidity: 30~85%
Application Scope
Adult, pediatric and neonatal  
Performance Specifications
Display: 10.4” color TFT
Resolution 640x480
Trace: 4 waveforms
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Indicator: Alarm indicator, Power indicator
QRS beep and alarm sound
Interface: In-System Programming Port
Battery: Rechargeable
Trend time: 1~72 Hours
Alarm: 3-level audible and visual alarm
Recorder: Built-in, thermal array, 2 channels
Record width: 48 mm (record paper 50 mm)
Record speed: 25mm/s, 50 mm/s
EGG
Input: 3-lead: R; L; F or RA; LA; LL
Lead selection: I, II, III
ECG waveform: 1 channel (the 2nd waveform cascade)
Gain selection: x0.25; x0.5; x1; x2; auto
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range: Adult:15~300bpm
Pediatric/Neonatal:15~350bpm
Accurancy: ±1bpm or ±1%, whichever is greater
Resolution: 1bpm
Protection: Withstand 4000VAC/50Hz
voltage in isolation
Against electrosurgical interference
and defibrillation
CMRR: Diagnostic mode: >85dB
  Monitoring mode: >105dB
Operating mode: >105dB
Calibration signal: 1mV±5%
Operation modes: Diagnostic, Monitor, Surgery
Bandwidth: 0.05~100Hz
Pace Detection: YES
Alarm range: Adult: 15~300bpm
Pediatric/Neonatal: 15~350bpm
S-T detection: YES
Measurement range: -2.0mV~2.0mV
Alarm range: -2.0mV~2.0mV
Arrhythmia analysis: YES
Pacemaking analysis: YES
Alarm : YES, audible and visual alarm, alarm
events recallable


Respiration
Method: RA-LL impedance
Measurement range: Adult: 6-120rpm
Pediatric/Neonatal: 6-150rpm
Resolution: 1rpm
Accuracy: ±2rpm
Alarm range: Adult:6~120rpm
Pediatric/Neonatyal: 6-150rpm
Apnea alarm: YES
NIBP
Method: Oscillometric
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/Kpa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10~270mmHg
Pediatric: 10~200mmHg
Neonatal: 10~135mmHg
Over-pressure protection: YES
Resolution: 1mmHg
Accuracy: Mean error and standard deviation per
ANSI/AMI SP-10
Alarm: Systolic, Diastolic, Mean
Temperature (Surface and Intracavity)
Measurement range:: 0~50 °C
Resolution: 0.1 °C
Accuracy: ± 0.2 °C (including probe)
Channel: 1 channel
Alarm range: 0~50 °C
SpO2
Measurement range: 0~100%
Resolution: ±2%
Accuracy: ±2 (70~100%); 0~69% unspecified
Alarm range: 0~100%
Pulse Rate: Range: 25~254bpm
Resolution: 1bpm
Accuracy: ±2bpm or 2% whichever is greater
Alarm range: 0-254bpm