M4 NOVA - Vital Signs Monitoring System

M4 <sup>NOVA</sup> - Vital Signs Monitoring System

Features

  • 8.4 inch superior resolution Colour TFT
  • Parameters include: ECG, RESP, NIBP, SPO2 ,
    Pulse Rate & Temp.
  • Optional: Single / Dual IBP, ETCO2
  • Fully digital monitoring, highly integrated technology
  • 7-lead ECG waveforms displayed in one screen
    simultaneously
  • ST segment analysis, 23 kinds of arrhythmia analysis
  • Function of OXY - CRG analysis
  • Maximum 72 hour data record, 120 items for alarm event records
  • Audio and visual comprehensive alarm
  • Built - in rechargeable battery
  • Suitable for adult, pediatrics, neonates

Description

M4NOVA -The Compact & Affordable Multipara Monitor - also called Medical Monitor, is a crucial instrument, being utilized in the critical care units of hospitals.

The affordable & light-weight solution: with a better battery back-up to monitor
the patients virtually in all the departments of the hospital.

The Ergonomically Designed Handle Provides Easy Portability.

Monitor Dimensions & Weight  
Dimension: 202 mm x 262mm x 110 mm
Weight: 3.4 Kg
Work Environment
Temperature Range: Work condition:        0 – 45°C
Storage condition:       -20 – 55°C
Humidity Range: Work at 45°C:      85%
Storage at 40°C:   93%
Electrical Specification: 100-250V AC, 50 / 60 Hz, Max input power 90VA
DC 12 – 20V, Max input current 4A
Scope: Newborns, Infants, Adults
Monitor Functional Specification  
Display: Color 8.4” TFT screen, resolution 640 x 480
Language Options: English
Indicators: 7-waveform display
Alarm indicating light
External DC supply indicating light
QRS voice & voice alarming
Interfaces: Measurement parameter cable interface
Power supply socket
Simulated signal output
(1V & 5V amplitude optional, tolerance <20%),
output impedance 50 Ω, signal delay <30ms
Battery: Chargeable up to 1 hour backup
Trend Time: 1 – 72 hours
Recorder: Optional
ECG Specification
Lead Input: 5-lead Cable:     RA; LA; RL; LL; C
Lead Method::    I; II; III; avR; avL; avF; V;                               CAL(calibration)
No. of channels:      7 channels
HR Gain: X0.5; X1; X2; X4; Automatic
Adult Measurement &
Alarming Range:

15 – 300 BPM
Newborn/Infant Measurement &
Alarming Range:
15 – 350 BPM 
Precision:   1%                            
Resolution:    ± 1 BPM
Sensitivity: >200uV (peak-to-peak value)
Differential Input Impedance: over 5 MΩ
CMR:  
Non-filtering mode  >60 dB                            
Filtering mode    >80 dB
Electrode Polarized Voltage Range: ± 300 mV
Leakage Current: less than 10uA
Protection
Electric Isolation: 4000V AC / 50 Hz voltage Defibrillation/Electric knife resistant, Grid/EMG resistant
Baseline Recovery Time: After defibrillation < 5 seconds
(under Filtering mode)
Scaling Signal: 1 mV (peak-to-peak value)
Accuracy: ± 3%
Frequency Response (bandwidth)
Filtering Mode: 0.5 – 25 Hz
Non-filtering Mode: 0.05 – 75 Hz
Alarm: Voice-alarm dual alarms, with review function
Pacing: Pacemaker works only after capturing pacing
RESP Specification
Method: RA-LL impedance method
RR Measurement & Alarming Range:
Adult:

7 – 100 BPM
Infant/Newborn: 7 – 100 BPM
Resolution: 1 BPM
Precision: ± 2 BPM
Differential Input Impedance: Over 2.5 MΩ, RA-LL lead
Choke Alarm: 10 – 40 seconds
NIBP Specification
Measurement Method: Automatic vibration
Work Mode: Manual / Automatic / Continuous
Unit:: mmHg
Adult: Systolic Pressure: 25 – 255 mmHg
Diastolic Pressure: 10 – 220 mmHg
Average Pressure: 20 – 235 mmHg
Overpressure Protection: dual protection (1) 300 mmHg (2) 300 ± 10% mmHg
Infant: Systolic Pressure: 20 – 180 mmHg
Diastolic Pressure: 10 – 150 mmHg
Average Pressure: 10 – 160 mmHg
Over Pressure Protection: 180 mmHg
Newborn: Systolic Pressure: 20 – 120 mmHg
Diastolic Pressure: 5 – 100 mmHg
Average Pressure: 10 – 110 mmHg
Overpressure Protection: dual protection (1) 300 mmHg (2) 300 ± 10% mmHg
Resolution: 1 mmHg
Precision: Tolerance < ± 5 mmHg, less than 8 mmHg
PR Range: 40 – 240 BPM
Systolic / Diastolic /
Average Pressure:
0 – 300 mmHg
Spo2 Specification
Measurement and
Alarm Range:
0-100 %
Resolution: 1 %
Precision: ± 2% (70 –100%); ± 3% (60–70 %);
(not specified < 60%)
Resolution: 1 BPM
Precision: ± 1%
TEMP Specification
Measurement & Alarm Range: 0 – 45°C
Resolution: 0.1°C
Precision: ± 0.1°C (circuit precision)
± 0.2°C (including TEMP sensor)
Alarm range: No. of Channels: