Associated Brands

Poet®IQ2 Anesthetic Gas Monitor

Poet<sup>®</sup>IQ<sub>2</sub> Anesthetic Gas Monitor

Features

  • State-of-the-art non-dispersive infrared (NDIR) technology identifies and measures five anesthetic agent gases: Halothane, Enflurane, Isoflurane, Desflurane and Sevoflurane.
  • Breath-by-breath O2 , CO2 , and N 2O monitoring.
  • Automatic or manual modes.
  • Gas flow sampled at 100, 150 and 200 ml/min.
  • Measurement accuracy is not affected by alcohol or ketones.
  • Fast warm-up time ensures full accuracy within minutes.
  • Auto-calibration.
  • Bright, real-time display of waveforms and numerical values provide instant notification of changing patient status.
  • Lightweight, portable design provides flexible
    workspace option.

Description

The Poet® anesthetic gas monitor is a compact stand-alone provides leading edge anesthesia gas monitoring.

A powerful monitoring tool - proprietary state-of-the-art digital 5-agent gas analysis technology. Versatile, reliable and incredibly compact. Designed for anesthesia applications in hospitals and outpatient surgery centers.

The systems reliable performance, ease of use, flexible design and affordable cost makes it the ideal monitoring solution for anesthesia applications in hospitals and surgical centers.

The Poet® IQ2 automatically identifies and quantifies inspired and expired O2, CO2, N2O, and five anesthetic agents. The system is compatible with color VGA
displays and has large screen output capability.

Gas Monitoring
Method: Sidestream;
Non-dispersive infrared (NDIR)
Identified Gases: Halothane, Enflurane, Isoflurane
Desflurane, Sevoflurane, O2, CO2, N2O
Concentration Units: Vol%, Torr, kPa, mmHg
Flow Rates: 100, 150 or 200 ml/min
Agent Detection
Measurement Range: Halothane:       0 to 10%
Enflurane:       0 to 10%
Isoflurane:       0 to 10%
Desflurane      0 to 20%
Sevoflurane     0 to 10%
CO2:             0 to 12.5%
N2O:             0 to 99%
O2:               0 to 100%
Measurement Accuracy: Agents:       ±0.1% abs. + 4% of reading
Co2:           ±0.2% abs. or 4% of reading
N2O::         ±1.5% abs. + 4% of reading
O2:             ±3 vol% (0 – 90%)
                 ±4 vol% (91 – 99%)

Time to Detect Agent: < 15 seconds @ 200 ml/min
Mixed Gas Threshold: 0.2 vol% +10% of total concentration
Agent Detect Resolution: 0.1 vol%
Measurement Accuracy: Agents:    450 msec
Co2:    350 msec
N2O::   400 msec
O2:    600 msec


Respiration Rate
Range: 1 to 60 Br/min
Accuracy: ±2 Br/min or 2% of reading
Trends
Occlusion Clearing: Automatic
Auto Zeroing: Occurs 30 to 60 minutes
Duration: 3.0 to 7.0 seconds
Manual user calibration not required
Temperature stabilized optical
assembly
Auto-calibration; verification
recommended once per year
Warm-up Time: 1 minute to first waveforms;
< 20 minutes to full accuracy
Alarms
Alarm Characteristics: EN 475, Adjustable with audible and
visual indications
Alarm Levels: High, Medium, Low Informational
Alarm Modes: Adult/Pediatric/Neonate
High and low limit settings for each
mode
Trends
Memory: 24 hours of stored data
Display: Tabular, Graphical
Display
Main Display: Active color TFT
Size: 5.5 in
Resolution: Internal: 320 x 240 pixels
External: 640 x 480 pixels
System Outputs
Com Ports: Com 1; RS 232 compatible,
Serial DB-9
Com 2; Serial/Analog, mini-DIN8
Video Port: Color VGA compatible,
High Density D-Sub 15
Power Requirements
Voltage: 100, 120, 220, 240 VAC; 50/60 Hz
Power Consumption: 40W typical
Battery: NiMH
Life: 1 hr typical
Recharge Time: 3 hrs typical
Mechanical
Weight: 13 lbs; 5.9 kg
Size (base unit): 6.5 in (H) x 11.0 in (W) x 12.0 in (D)
16.5 cm (H) x 27.9 cm (W) x 30.5 cm (D)
Environmental
Operating Temperature: 59° to 95°F (15° to 35°C)
Storage Temperature: 23° to 122°F (-5° to 50°C)
Operating/Storage
Humidity:

15% to 95%, non condensing
Altitude: -1000 ft to 10,000 ft (-300 m to 3,000 m)
Classification
Electrical Protection: Class I Equipment
Degree of Protection: Type CF, Defibrillator-Proof
Safety: Protection Against Ingress: